Data Centre Infrastructure Management

Ensures uninterrupted operational continuity and optimizes energy costs by monitoring critical infrastructure components such as air conditioning, UPS, PDU, and generators, along with environmental conditions, 24/7 in data centers and server rooms.

Data centers and server rooms are high-density facilities containing critical components such as servers, storage units, network infrastructure, and power systems, where continuous operation is mandatory. Whether it is a corporate server room or a large-scale data center, dozens of infrastructure components including air conditioning systems, UPS units, PDUs, generators, cooling capacity, and physical access must be kept under control simultaneously in these environments.

Uncontrolled critical infrastructure components lead to serious consequences in data centers and server rooms: air conditioning failure raises cabinet temperatures to critical levels within minutes, UPS or PDU outages result in complete loss of service, and generator startup delays can cause damage that is difficult to reverse. Traditional periodic checks are inadequate in data center conditions that can change within seconds; failures are often only detected after damage has occurred.

With Noctua software and BirSens hardware, all critical parameters including air conditioning, UPS, PDU, generator, and environmental conditions in the data center and server room infrastructure are continuously monitored, instant notifications are sent when thresholds are exceeded, and historical data is reported. This enables data center managers to maximize uptime, optimize power usage effectiveness (PUE), and ensure compliance with international standards.

Instant monitoring of critical systems such as air conditioning, UPS, PDU, generators, and environmental conditions in data center and server room infrastructure is critical for ensuring uninterrupted service continuity and extending hardware life.

International data center standards such as Uptime Institute Tier Classification, ASHRAE TC 9.9 thermal guidelines, EN 50600 European data center standards, and ISO/IEC 27001 information security management systems require continuous monitoring, recording, and documentation of environmental conditions. Compliance frameworks like PCI DSS and SOC 2 also expect physical security and environmental control mechanisms to be provable. Therefore, it is not merely a matter of instantaneous measurement, continuous data recording, tiered alarm management, and audit-oriented reporting infrastructure are of great importance.

Furthermore, modern data centers and server rooms are complex structures consisting of multiple halls, cabinet rows, and cooling zones. Monitoring hot aisle / cold aisle arrangements, cabinet-based energy consumption, and cooling capacity via a centralized platform is a strategic necessity for capacity planning, energy optimization, and failure prediction.

Key Risks Encountered in Data Center Infrastructure

thermostat

Temperature and Humidity Deviations

According to ASHRAE guidelines, server inlet temperature should be maintained between 18-27°C and relative humidity between 20-80%. Exceeding these limits leads to performance loss due to processor throttling, short circuits caused by condensation, and shortened hardware lifespan. Imbalances between hot and cold aisles, hotspot formation within cabinets, and cooling leaks are the most common scenarios.

power

Power Outages and UPS Failures

Power continuity is the most critical factor in data centers. Grid outages, decreased UPS battery capacity, transfer switch (ATS) failures, and generator startup delays can cause complete service loss within seconds. Continuous monitoring of UPS load ratio, battery health, and grid quality is mandatory to prevent potential outages.

ac_unit

Cooling System Failures

Failures in CRAC/CRAH units, in-row coolers, or chiller systems can raise cabinet temperatures to critical levels within minutes. Cooling capacity not being proportional to instantaneous load, fan failures, refrigerant leaks, and condensation drainage blockages are the most frequent cooling problems in data centers.

water_damage

Water Leakage and Condensation Risks

Condensation water accumulating under cooling units, water pipe leaks under raised floors, or fire suppression system leaks can cause electrical contacts, corrosion inside cabinets, and hardware damage. Early detection of water leakage, especially under raised floors and in cable trays, is of critical importance.

electric_bolt

Energy Inefficiency and High PUE

Energy costs in data centers can constitute 30-60% of total operating expenses. Over-operation of cooling systems, unbalanced load distribution, missed free cooling opportunities, and inability to detect zombie servers raise the PUE (Power Usage Effectiveness) value, leading to energy waste.

local_fire_department

Fire and Smoke Risks

Short circuits caused by overheating in electrical cables, thermal runaway in UPS-batteries or dust accumulation increase the risk of fire. By continuously measuring airborne particle density using air quality sensor and monitoring trends in temperature increases, the fire risk can be detected at an earlier stage before damage occurs.

shield_lock

Physical Security Breaches

Unauthorized cabinet access, leaving room and cabinet doors open, or environmental security vulnerabilities pose serious risks to data security and compliance requirements. Centralised control of door contact sensors, acces management, alongside the integrated monitor of door contact sensors, access control devices, and CCTV recordings integrated with environmental data, is essential for comprehensive security.

Data center infrastructure monitoring

What Does Birtech Provide in This Area?

End-to-end solution from hardware to software, from critical infrastructure monitoring to energy management:

memory

Field-Proven BirSens Hardware Family

With custom-designed rack-type control modules, temperature/humidity sensors, strip and point water leak sensors, door contact sensors, air quality sensors, access control solutions, and motion-sensitive camera solutions, the BirSens hardware family provides high precision, wide measurement range, and uninterrupted data transmission.

hub

Brand Agnostic Critical Infrastructure Integration

Noctua data center software enables monitoring and management of all critical infrastructure components, such as air conditioning, UPS, PDU, energy analyzers, and generators, through a single platform regardless of brand and model. Devices from different manufacturers are unified in a common infrastructure, providing a centralized and holistic control experience.

dashboard_customize

Dashboard Module

It offers an advanced visualisation framework that allows users to fully customise their monitoring screens. Drag-and-drop panels can be created as templates suitable for different screen resolutions and Video Wall structures. Not only sensor data but also operational information such as event reports and access reports can be displayed on the dashboard. Furthermore, an interactive and dynamic monitoring experience is provided with live camera images, text, and visual fields.

neurology

Super Sensor

Enables users to create their own virtual sensors using existing sensor data. Through a drag-and-drop interface requiring no coding knowledge, data from one or more sensors can be combined using mathematical or logical operations (average, maximum, difference, and/or conditions, etc.). These virtual sensors can perform real-time analysis, generate alarms, and create reports according to defined rules. Super Sensor makes physical sensors more meaningful, enabling easy modeling of complex scenarios and automation of proactive monitoring processes. For example: "If cabinet inlet temperature exceeds 30°C AND the compressor of the relevant air conditioner is not running, CREATE CRITICAL ALARM and CALL the on-duty team" — such a multi-condition scenario can be defined within minutes using drag-and-drop.

inventory_2

Inventory Management

Enables all physical assets in the infrastructure to be organized, traceable, and manageable through a single platform. Devices, sensors, cabinets, racks, network equipment, energy, and climate control systems can be defined in detail, and up-to-date inventory records can be easily tracked. Documents such as brochures, user manuals, and maintenance reports can be added to each inventory record; users can write special notes for these inventories to enrich information sharing. The module visually displays the physical positions of devices within the cabinet in front and rear views; device layouts are displayed exactly corresponding to the actual cabinet structure.

bolt

Energy Cost and PUE Management

Provides the ability to monitor energy consumption, costs, and efficiency ratios in data centers from a single screen. Consumption is tracked by location, device, or category through energy analyzers, current meters, and PDUs; energy costs can be reported in both kWh and local currency. Power Usage Effectiveness (PUE) value is automatically calculated to monitor energy efficiency. Consumption and cost limits can be set by creating daily, weekly, or monthly target cards; the system sends automatic notifications when targets are exceeded. Furthermore, firms providing energy leasing can offer consumption reports based on space, cabinet, or PDU port to their customers, and multi-layered energy management can be performed.

security

Physical Security Management Module

Combines access control, monitoring, and security event management in data centers into a single platform. With the Integrated Door Security feature, each door can be defined; door sensors, access control devices (card or biometric), and cameras can be added to these doors. When a door is opened, the system evaluates these components as a single event and produces a single notification; thus preventing notification pollution and making reports more connected and simplified. Shift definitions can be created to grant access authorization only during relevant shift periods, and user data can be automatically transferred to biometric devices through LDAP integration.

notifications_active

Notification Efficiency and Optimization

Noctua offers a focused and efficient system management experience by ensuring users receive only important and meaningful notifications. With decreasing notification frequency over time, delivery intervals automatically become less frequent as events age. With location event summaries, instead of separate emails for each event, all open events within a location-based single summary email are delivered at certain periods. Newly occurring events are delivered immediately as individual notifications; ongoing events are included in summary reports after a specified time. With the door notification feature, door sensor, access control device, and camera movements are combined under a single event.

map

2D Visualization and Heat Map

Data center floor plans can be visualized in 2D with Noctua. Which cabinet has a hotspot, regions where cooling capacity is insufficient, cabinet rows where energy density increases, or hot/cold aisle imbalances are detected directly through the heat map. Thus, optimization decisions such as cabinet placement, cooling capacity planning, and load distribution are made based on data.

smartphone

24/7 Remote Access and Mobile Control

With Android and iOS applications, you can receive instant notifications from anywhere, view the status of all halls and cabinets, and quickly access basic reports. When a critical alarm arrives during night hours or weekends, you can evaluate the situation from your phone and coordinate the necessary intervention.

verified

Audit and Compliance Reporting

Reports on historical environmental conditions, energy consumption, and physical access reports required by standards and compliance frameworks such as Uptime Institute, EN 50600, ISO/IEC 27001, PCI DSS, and SOC 2 can be easily generated. Sensor reliability can be documented with TURKAK-accredited calibration certificates.

support_agent

Support That Ensures Continuity

Operational continuity of your systems is protected with maintenance, calibration, and support services provided under SensCare®. Continuous technical support is provided in accordance with the 24/7 operating requirements of the data center.

Reliability Is Proven in the Field

Birtech infrastructure serves continuously in a wide range from corporate data centers to colocation facilities, from the financial sector to public infrastructures. Systems operating in the field for years are the most concrete proof of reliability.

Customer Experience

Those who use Birtech's solutions in the IT infrastructure field tell best how it makes a difference in the field. You can listen to the experience and satisfaction evaluation regarding the monitoring infrastructure implemented in IT areas at Istanbul Medipol University directly from the field.

Data Center Customer Experience Video
play_arrow

Let Us Design the Solution Tailored to Your Needs

Let us create a custom monitoring system based on your cabinet capacity, cooling architecture, energy infrastructure, and compliance requirements. Submit your request, and our team will contact you within the same day in most cases, within 24 hours at the latest.

arrow_forward Contact Us